The Intergas Kompakt Solo HRE A is a boiler without an integrated hot water supply. A solo boiler is the ideal solution if you do not need a combi boiler for hot water preparation. Additionally, the Intergas Kompakt Solo HRE can be easily combined with an indirectly heated boiler. This allows you to choose the combination that best suits your needs and preferences in terms of hot water comfort.
The Intergas Kompakt Solo HRE A is equipped with a stepless modulating control system that automatically adjusts the boiler's output to match the heating demand.
All components of the Intergas Kompakt Solo HRE are easily accessible. In addition, the front casing is removable, allowing the unit to be placed without issue in a kitchen cupboard. The maintenance of a condensing boiler has never been so simple.
Feature | Value |
---|---|
Brand | Intergas |
Supplier Code | 040347 |
EAN Code | 8718556040341 |
Discount Group | 051 |
Width | 450 mm |
Height | 650 mm |
Depth | 240 mm |
Power Supply | 230 V |
Energy Efficiency Class | A |
Flow Connection | Compression |
Return Connection | Compression |
Closed Unit | Yes |
Water Heating Energy Efficiency (Nwh) | 0 % |
SEER (Ns) under average conditions | 93 |
Supplementary Power Consumption at Full Load (ELmax) | 0.035 kW |
Useful Heat Output at Nominal Heat Output and Operation at High Temperature (P4) | 22.8 kW |
Useful Efficiency at Nominal Heat Output and Operation at High Temperature (n4) | 86.8 % |
Supplementary Power Consumption in Standby Mode (Psb) | 0.002 kW |
Standby Heat Loss (Pstby) | 0.038 kW |
Heat Exchanger Material | Aluminum |
Built-in Pump Switch | Yes |
Gas Certification VR/SV | Yes |
Gas Certification NZ | No |
Nominal Load Lower Value | 23.7 kW |
Nominal Load Upper Value | 26.4 kW |
Min. Operating Pressure | 0.5 bar |
Max. Gas Inlet Pressure | 30 mbar |
Built-in Weather Dependent Regulator | Yes |
Built-in Expansion Vessel | No |
Nominal Output 80-60 °C | 22.8 kW |
Max. Flow Temperature (Operating Temperature) | 90 °C |
Built-in Fill/Drain Valve | No |
Built-in Overpressure Valve | No |
External Pipe Diameter Flow | 22 mm |
External Pipe Diameter Return | 22 mm |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | End Cap |
Nominal Channel Diameter Air Supply | 80 mm |
Flue Gas Connection | End Cap |
Condensate Connection | Flexible |
External Pipe Diameter Condensate | 25.4 mm |
Min. Gas Inlet Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Certification VR | No |
Nominal Channel Diameter Flue Gas | 80 mm |
Burner Control High/Low | No |
Burner Control Modulating | Yes |
Built-in Manometer | Yes |
Gas Certification HR | Yes |
Efficiency | 107 % |
Open/Closed Unit | No |
Pilot Flame | No |
Second Return Connection | No |
Regulation Signal On/Off | Yes |
Regulation Signal High/Low | No |
Regulation Signal 0-10V | No |
Regulation Signal OpenTherm | Yes |
Operation as Open Unit (Air Supply) Possible | No |
Nominal Output 50-30 °C | 23.4 kW |
Suitable for Propane | Yes |
Suitable for Butane | No |
Suitable for Methane | No |
Max. Allowed Operating Pressure | 3 bar |
Conversion Kit Required | Yes |