The Intergas Kompakt Solo HRE A is a central heating boiler without an integrated hot water supply. A solo boiler is the solution if you do not need a combination boiler for hot water production. Additionally, the Intergas Kompakt Solo HRE can easily be combined with an indirectly heated water tank. This allows you to choose the combination that best fits your needs and preferences in terms of hot water comfort.
The Intergas Kompakt Solo HRE A is equipped with a stepless modulating control system, which ensures that the boiler's power is automatically adjusted to the heat demand.
All components of the Intergas Kombi Kompakt HRE Solo are easily accessible. Furthermore, the front casing can be removed, allowing the device to be placed in a kitchen cupboard without any issues. Maintenance of an HR boiler has never been so easy.
Feature | Value |
---|---|
Brand | Intergas |
Supplier Code | 040407 |
EAN Code | 8718556040402 |
Discount Group | 051 |
Width | 450 mm |
Height | 710 mm |
Depth | 240 mm |
Power Supply | 230 V |
Energy Efficiency Class | A |
Flow Connection | Compression |
Return Connection | Compression |
Closed Construction | Yes |
Energy Efficiency for Water Heating (Nwh) | 0 % |
SEER (Ns) under average conditions | 92 |
Supplementary Electricity Consumption at Full Load (ELmax) | 0.1 kW |
Useful Heat Output at Nominal Heat Output and High Temperature Operation (P4) | 40.9 kW |
Useful Efficiency at Nominal Heat Output and High Temperature Operation (n4) | 86.8 % |
Supplementary Electricity Consumption in Standby Mode (Psb) | 0.004 kW |
Standby Heat Loss (Pstby) | 0.038 kW |
Heat Exchanger Material | Aluminum |
Built-in Pump Control | Yes |
Gas Certification VR/SV | Yes |
Gas Certification NZ | No |
Nominal Load Lower Value | 42.5 kW |
Nominal Load Upper Value | 47.2 kW |
Min. Operating Pressure | 0.5 bar |
Max. Gas Supply Pressure | 30 mbar |
Built-in Weather-Dependent Regulator | Yes |
Built-in Expansion Tank | No |
Nominal Power 80-60 °C | 40.9 kW |
Max. Flow Temperature (Operating Temperature) | 90 °C |
Built-in Fill/Drain Valve | No |
Built-in Pressure Relief Valve | No |
External Pipe Diameter Flow | 22 mm |
External Pipe Diameter Return | 22 mm |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Mofeind |
Nominal Channel Diameter Air Supply | 80 mm |
Flue Gas Connection | Mofeind |
Condensate Connection | Flexible |
External Pipe Diameter Condensate | 25.4 mm |
Min. Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Certification VR | No |
Nominal Channel Diameter Flue Gas Outlet | 80 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Gas Certification HR | Yes |
Efficiency | 107 % |
Open/Closed Design | No |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | No |
Control Signal OpenTherm | Yes |
Operation as Open Design (Air Supply) Possible | No |
Nominal Power 50-30 °C | 42.2 kW |
Suitable for Propane | Yes |
Suitable for Butane | No |
Suitable for Methane | No |
Max. Allowable Operating Pressure | 3 bar |
Conversion Kit Required | Yes |