The Intergas Xtreme combi boiler is a reliable and efficient solution for heating water and the home. With its modulating burner control, built-in weather-dependent regulator, and energy efficiency class A for both space heating and water heating, it saves energy and increases comfort in the home.
The Xtreme utilizes the proven concept of a dual aluminum two-in-one heat exchanger. The patented Intergas design with two separate copper circuits ensures optimal heat transfer and minimal heat loss. The second heat exchanger (WTW unit) is integrated into the flue gas discharge of the unit, which further cools the combustion gases. Additionally, the residual heat from the flue gases is used during space heating to preheat the domestic hot water.
To prevent damage to the additional heat exchanger in the flue gas pipe (the corrugated stainless steel hose), it is recommended to install the supplied water hammer arrestor in the hot water pipe – at least 60 cm away from the unit.
All Xtreme units are Hybrid Ready, meaning these units are suitable for expansion into a hybrid heat pump system. This can be done at the time of purchase or later on.
All Xtreme units come standard with an RF module and are fully prepared for the future. This makes it even easier to control the heating via smartphone in combination with the Intergas Gateway, the Comfort Touch thermostat, and the Comfort Touch app.
This boiler is equipped with an 80/125mm concentric flue gas discharge.
Feature | Value |
---|---|
Brand | Intergas |
Supplier Code | 015164 |
EAN Code | 8718556215169 |
Discount Group | 051 |
Width | 450 mm |
Depth | 240 mm |
Voltage Supply | 230 V |
Supply Connection | Compression fittings |
Return Connection | Compression fittings |
Closed Model | Yes |
Nominal Load Upper Value Hot Water | 36.3 kW |
Nominal Load Lower Value Hot Water | 32.7 kW |
Energy Efficiency for Water Heating (Nwh) | 92% |
SEER (Ns) under Average Conditions | 94 |
Capacity Profile | XXL |
Energy Efficiency Class for Space Heating | A |
Energy Efficiency Class for Water Heating | A |
Additional Electricity Consumption at Full Load (ELmax) | 0.045 kW |
Useful Heat Output at Nominal Heat Output and High-Temperature Operation (P4) | 32 kW |
Useful Efficiency at Nominal Heat Output and High-Temperature Operation (n4) | 88.3% |
Additional Electricity Consumption in Standby Mode (Psb) | 0.002 kW |
Standby Heat Loss (Pstby) | 0.038 kW |
With Built-in Economizer | No |
Material of Heat Exchanger | Aluminum |
Adjustable Heating Power | Yes |
Flow Threshold | 1.5 l/min |
Built-in Pump Switching | Yes |
Gas Certification VR/SV | Yes |
Gas Certification NZ | Yes |
CW Label | 5 |
Nominal Load Lower Value | 32.7 kW |
Nominal Load Upper Value | 36.3 kW |
Min. Operating Pressure | 0.5 bar |
Max. Gas Supply Pressure | 30 mbar |
Hot Water Capacity at 60 °C | 9 l/min |
Built-in Weather-Dependent Regulator | Yes |
Built-in Expansion Vessel | No |
Nominal Power 80-60 °C | 32 kW |
Max. Flow Temperature (Operating Temperature) | 90 °C |
Built-in Filling/Draining Valve | No |
Built-in Overpressure Valve | No |
External Pipe Diameter for Supply | 22 mm |
External Pipe Diameter for Return | 22 mm |
Fuel Connection | Compression fittings |
External Pipe Diameter for Fuel | 15 mm |
Air Supply Connection | Muff end |
Nominal Pipe Diameter for Air Supply | 125 mm |
Flue Gas Discharge Connection | Muff end |
External Pipe Diameter for Cold Water Pipe | 15 mm |
External Pipe Diameter for Hot Water Pipe | 15 mm |
Condensate Connection | Flexible |
External Pipe Diameter for Condensate | 25.4 mm |
Min. Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Certification VR | No |
Cold Water Connection | Compression fittings |
Hot Water Connection | Compression fittings |
Nominal Pipe Diameter for Flue Gas Discharge | 80 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Gas Certification HR | Yes |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | No |
Control Signal OpenTherm | Yes |
Operates as Open Design (Air Supply) | Yes |
Suitable for Propane | Yes |
Suitable for Butane | No |
Suitable for Methane | No |
Max. Allowable Operating Pressure | 3 bar |
Conversion Kit Required | Yes |
Built-in Inlet Combination | No |