The intelligent Calenta Ace is ready for the (digital) future – thanks to the new device control system (eSmart Inside). The Calenta Ace boiler features brass hydro blocks. The heat exchanger used in the Calenta Ace has a surface treatment, eliminating the need for physical cleaning. Installing this boiler is simple, as the mounting bracket includes an integrated spirit level.
The system can optionally be expanded with a (semi-)automatic refill unit, allowing it to be refilled automatically and intelligently via the boiler's control panel, the eTwist, or the convenient eTwist app.
Feature | Value |
---|---|
Brand | Remeha |
Supplier Code | 7672227 |
EAN Code | 8713809289041 |
Discount Group | 005 |
Width | 450 mm |
Height | 690 mm |
Depth | 450 mm |
Supply Voltage | 230 V |
Number of Phases | 1 |
Energy Efficiency Class | A |
Material Quality | Other |
Flow Connection | Compression Fitting |
Return Connection | Compression Fitting |
Frequency | 50 Hz |
Connection Voltage | 196 - 253 V |
Closed System | Yes |
SEER (Ns) under Average Conditions | 95 |
SEER (Ns) under Cold Conditions | 99.6 |
SEER (Ns) under Warm Conditions | 89.3 |
Supplementary Power Consumption at Full Load (ELmax) | 0.05 kW |
Useful Heat Output at High Temperature (P4) | 34.5 kW |
Efficiency at High Temperature (n4) | 89.3 % |
Supplementary Power Consumption in Standby Mode (Psb) | 0 kW |
Standby Heat Loss (Pstby) | 0.054 kW |
Max. Hydrogen Percentage for Mixing with Natural Gas | 20 % |
Suitable for Low-Calorific Natural Gas | Factory Default |
Suitable for High-Calorific Natural Gas | Manually Adjustable |
Suitable for Propane | Manually Adjustable |
Suitable for Butane | Not Suitable |
Suitable for Methane | Automatically Adjustable |
Suitable for LPG | Not Suitable |
Suitable for Hydrogen | Manually Adjustable |
Heat Exchanger Material | Aluminum |
Built-in Pump Control | Yes |
Gaskeur VR/SV | No |
Gaskeur NZ | Yes |
Nominal Lower Load | 34.8 kW |
Nominal Upper Load | 38.7 kW |
Min. Operating Pressure | 0.8 bar |
Min. Return Temperature | 20 °C |
Max. Gas Supply Pressure | 30 mbar |
Built-in Weather-Dependent Controller | Yes |
Built-in Expansion Vessel | No |
Water-Side Resistance at ΔT 20 °C | 46 kPa |
Nominal Power 80-60 °C | 34.5 kW |
Max. Flow Temperature | 90 °C |
Max. Operating Pressure | 3 bar |
Built-in Fill/Drain Valve | No |
Built-in Overpressure Valve | Yes |
External Pipe Diameter Flow | 22 mm |
External Pipe Diameter Return | 22 mm |
Fuel Connection | Other |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Push-Fit |
Nominal Duct Diameter Air Supply | 100 mm |
Flue Gas Outlet Connection | Push-Fit |
Condensate Connection | Other |
External Pipe Diameter Condensate | 25 mm |
Min. Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gaskeur VR | No |
Nominal Duct Diameter Flue Gas Outlet | 60 mm |
Burner Control High/Low | No |
Burner Control Modulating | Yes |
External Pipe Diameter Expansion Connection | 0 mm |
Built-in Manometer | Yes |
Condensing Technology | Yes |
Gaskeur HR | Yes |
Efficiency | 99.1 % |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | Yes |
Control Signal OpenTherm | Yes |
Operation as an Open System Possible | Yes |
Nominal Power 50-30 °C | 35.6 kW |
Suitable for Propane | Yes |
Suitable for Butane | No |
Suitable for Methane | Yes |
Max. Permissible Operating Pressure | 3 bar |
Nominal Diameter Flow | Other |
Nominal Diameter Return | Other |
Nominal Diameter Fuel | Other |
Nominal Diameter Condensate | DN 25 |
Conversion Kit Required | No |
Gaskeur HR | Yes |
Gaskeur NZ | No |