Do you have a question about this product?
Our employee is happy to help you find the right product
With the Remeha Calenta Ace Combi Comfort System, you get the best combination of ultimate heating comfort and energy savings for your home. This smart combination of the high-quality HR boiler and a smart eTwist thermostat is perfectly aligned to ensure optimal performance.
Calenta Ace Boiler
The intelligent Calenta Ace is future-proof (digitally) thanks to the new device control (eSmart Inside). The Calenta Ace boiler is equipped with brass hydroblocks. The heat exchanger used in the Calenta Ace has a surface treatment, so it does not need to be physically cleaned. Installing the boiler is simple thanks to the integrated level in the mounting bracket.
This model is equipped with a concentric flue gas outlet.
Smart eTwist Thermostat
The eTwist is designed as a modulating room thermostat that efficiently controls the heating and cooling system. It has a wired connection to the device. It is possible to connect the eTwist via Wi-Fi to the internet, so the thermostat can be controlled via an app on a mobile device.
Technical Specifications:
Feature | Value |
---|---|
Brand | Remeha |
Supplier Code | 7672231 |
EAN Code | 8713809289089 |
Width | 450 mm |
Height | 690 mm |
Depth | 450 mm |
Voltage | 230 V |
Number of Phases | 1 |
Material Quality | Other |
Flow Connection | Compression |
Return Connection | Compression |
Nominal Voltage | 196 - 253 V |
Frequency | 50 Hz |
Closed Version | Yes |
Nominal Domestic Hot Water Power | 38.5 kW |
Nominal Maximum Load Domestic Hot Water | 43.1 kW |
Nominal Minimum Load Domestic Hot Water | 38.8 kW |
Energy Efficiency of Water Heating (Nwh) | 87 % |
SEER (Ns) under average conditions | 98 |
SEER (Ns) under cooler conditions | 99.6 |
SEER (Ns) under warmer conditions | 89.3 |
Capacity Profile | XXL |
Energy Efficiency Class Space Heating | A+ |
Energy Efficiency Class Water Heating | A |
Nominal Diameter Hot Water | DN 15 |
Additional Power Consumption at Full Load (ELmax) | 0.005 kW |
Useful Heat Output at Nominal Output and High-Temperature Operation (P4) | 34.5 kW |
Useful Efficiency at Nominal Output and High-Temperature Operation (n4) | 89.3 % |
Additional Power Consumption in Standby Mode (Psb) | 0.004 kW |
Standby Heat Loss (Pstby) | 0.054 kW |
With Built-in Economizer | Yes |
Energy Efficiency Space Heating | 98 % |
Hot Water Flow Rate according to EN 13203-1 | 20.3 l/min |
Heat Exchanger Material | Aluminum |
Adjustable Heating Power | Yes |
Nominal Diameter Cold Water | DN 15 |
Minimum Flow Rate | 1.5 l/min |
Built-in Pump Switch | Yes |
Gas Approval VR/SV | No |
Gas Approval NZ | Yes |
CW Label | 5 |
Nominal Minimum Load | 34.8 kW |
Nominal Maximum Load | 38.7 kW |
Minimum Operating Pressure | 0.8 bar |
Minimum Return Temperature | 20 °C |
Maximum Gas Supply Pressure | 30 mbar |
Domestic Hot Water Capacity at 60 °C | 11 l/min |
Built-in Weather-Dependent Regulator | Yes |
Built-in Expansion Vessel | No |
Hydronic Resistance at ΔT 20 °C | 46 kPa |
Nominal Output 80-60 °C | 34.5 kW |
Maximum Flow Temperature (Operating Temperature) | 90 °C |
Maximum Operating Pressure | 3 bar |
Built-in Fill/Drain Valve | No |
Built-in Pressure Relief Valve | Yes |
External Pipe Diameter Flow | 22 mm |
External Pipe Diameter Return | 22 mm |
Fuel Connection | Compression |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Push-fit |
Nominal Channel Diameter Air Supply | 100 mm |
Flue Gas Outlet Connection | Push-fit |
External Pipe Diameter Cold Water | 15 mm |
External Pipe Diameter Hot Water | 15 mm |
Condensate Connection | Other |
External Pipe Diameter Condensate | 25 mm |
Minimum Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Approval VR | No |
Cold Water Connection | Compression |
Hot Water Connection | Compression |
Nominal Channel Diameter Flue Gas Outlet | 60 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Condensing | Yes |
Gas Approval HR | Yes |
Efficiency | 99.1 % |
Pilot Light | No |
Second Return Connection | No |
On/Off Control Signal | Yes |
High/Low Control Signal | No |
0-10V Control Signal | Yes |
OpenTherm Control Signal | Yes |
Operation Possible as Open Version (Air Supply) | Yes |
Nominal Output 50-30 °C | 35.6 kW |
Suitable for Propane | Yes |
Suitable for Butane | No |
Suitable for Methane | Yes |
Maximum Allowable Operating Pressure | 3 bar |
Nominal Diameter Flow | Other |
Nominal Diameter Return | Other |
Nominal Diameter Fuel | DN 15 |
Hot Water Stock | 1 l |
Nominal Diameter Condensate | DN 25 |
Conversion Kit Required | No |
Built-in Inlet Combination | No |
CW Label | 5 |
Gas Approval HR | Yes |
Gas Approval NZ | Yes |
Our employee is happy to help you find the right product
Deliverytime