With the Remeha Calenta Ace Combi Comfort System, you get the best combination of ultimate heating comfort and energy savings for your home. This smart combination of the high-quality HR boiler and a smart eTwist thermostat is perfectly aligned to ensure optimal performance.
Calenta Ace Boiler
The intelligent Calenta Ace is future-proof (digitally) thanks to the new device control (eSmart Inside). The Calenta Ace boiler is equipped with brass hydroblocks. The heat exchanger used in the Calenta Ace has a surface treatment, so it does not need to be physically cleaned. Installing the boiler is simple thanks to the integrated level in the mounting bracket.
This model is equipped with a concentric flue gas outlet.
Smart eTwist Thermostat
The eTwist is designed as a modulating room thermostat that efficiently controls the heating and cooling system. It has a wired connection to the device. It is possible to connect the eTwist via Wi-Fi to the internet, so the thermostat can be controlled via an app on a mobile device.
Technical Specifications:
Feature | Value |
---|---|
Brand | Remeha |
Supplier Code | 7672231 |
EAN Code | 8713809289089 |
Width | 450 mm |
Height | 690 mm |
Depth | 450 mm |
Voltage | 230 V |
Number of Phases | 1 |
Material Quality | Other |
Flow Connection | Compression |
Return Connection | Compression |
Nominal Voltage | 196 - 253 V |
Frequency | 50 Hz |
Closed Version | Yes |
Nominal Domestic Hot Water Power | 38.5 kW |
Nominal Maximum Load Domestic Hot Water | 43.1 kW |
Nominal Minimum Load Domestic Hot Water | 38.8 kW |
Energy Efficiency of Water Heating (Nwh) | 87 % |
SEER (Ns) under average conditions | 98 |
SEER (Ns) under cooler conditions | 99.6 |
SEER (Ns) under warmer conditions | 89.3 |
Capacity Profile | XXL |
Energy Efficiency Class Space Heating | A+ |
Energy Efficiency Class Water Heating | A |
Nominal Diameter Hot Water | DN 15 |
Additional Power Consumption at Full Load (ELmax) | 0.005 kW |
Useful Heat Output at Nominal Output and High-Temperature Operation (P4) | 34.5 kW |
Useful Efficiency at Nominal Output and High-Temperature Operation (n4) | 89.3 % |
Additional Power Consumption in Standby Mode (Psb) | 0.004 kW |
Standby Heat Loss (Pstby) | 0.054 kW |
With Built-in Economizer | Yes |
Energy Efficiency Space Heating | 98 % |
Hot Water Flow Rate according to EN 13203-1 | 20.3 l/min |
Heat Exchanger Material | Aluminum |
Adjustable Heating Power | Yes |
Nominal Diameter Cold Water | DN 15 |
Minimum Flow Rate | 1.5 l/min |
Built-in Pump Switch | Yes |
Gas Approval VR/SV | No |
Gas Approval NZ | Yes |
CW Label | 5 |
Nominal Minimum Load | 34.8 kW |
Nominal Maximum Load | 38.7 kW |
Minimum Operating Pressure | 0.8 bar |
Minimum Return Temperature | 20 °C |
Maximum Gas Supply Pressure | 30 mbar |
Domestic Hot Water Capacity at 60 °C | 11 l/min |
Built-in Weather-Dependent Regulator | Yes |
Built-in Expansion Vessel | No |
Hydronic Resistance at ΔT 20 °C | 46 kPa |
Nominal Output 80-60 °C | 34.5 kW |
Maximum Flow Temperature (Operating Temperature) | 90 °C |
Maximum Operating Pressure | 3 bar |
Built-in Fill/Drain Valve | No |
Built-in Pressure Relief Valve | Yes |
External Pipe Diameter Flow | 22 mm |
External Pipe Diameter Return | 22 mm |
Fuel Connection | Compression |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Push-fit |
Nominal Channel Diameter Air Supply | 100 mm |
Flue Gas Outlet Connection | Push-fit |
External Pipe Diameter Cold Water | 15 mm |
External Pipe Diameter Hot Water | 15 mm |
Condensate Connection | Other |
External Pipe Diameter Condensate | 25 mm |
Minimum Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Approval VR | No |
Cold Water Connection | Compression |
Hot Water Connection | Compression |
Nominal Channel Diameter Flue Gas Outlet | 60 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Condensing | Yes |
Gas Approval HR | Yes |
Efficiency | 99.1 % |
Pilot Light | No |
Second Return Connection | No |
On/Off Control Signal | Yes |
High/Low Control Signal | No |
0-10V Control Signal | Yes |
OpenTherm Control Signal | Yes |
Operation Possible as Open Version (Air Supply) | Yes |
Nominal Output 50-30 °C | 35.6 kW |
Suitable for Propane | Yes |
Suitable for Butane | No |
Suitable for Methane | Yes |
Maximum Allowable Operating Pressure | 3 bar |
Nominal Diameter Flow | Other |
Nominal Diameter Return | Other |
Nominal Diameter Fuel | DN 15 |
Hot Water Stock | 1 l |
Nominal Diameter Condensate | DN 25 |
Conversion Kit Required | No |
Built-in Inlet Combination | No |
CW Label | 5 |
Gas Approval HR | Yes |
Gas Approval NZ | Yes |