The Inventum Spaarpomp Ventilation Heat Pump is a hybrid heat pump that works in combination with the central heating boiler (CV boiler). The Spaarpomp uses the extracted ventilation air from the home. The energy from the extracted warm air is reused for heating the central heating water, preventing the heat from being lost. On very cold days, the central heating boiler assists the Spaarpomp. During the other, less cold months, the Spaarpomp operates independently and heats the house by itself.
Includes ventilation Inventum has developed the Spaarpomp, a hybrid ventilation heat pump without an outdoor unit, which is easily installed inside the house or apartment. The Spaarpomp replaces the mechanical ventilation unit, ensuring the house is optimally ventilated. Most importantly, the Inventum Spaarpomp heats the home and ensures a comfortable and healthy indoor climate.
Easy installation and very compact The Inventum Spaarpomp Ventilation Heat Pump offers an intentional and simple solution for installers and homeowners. The Spaarpomp is compact, meaning no large units (outdoor unit) need to be placed in the garden or on the roof, and there is no mess or noise in the attic. Additionally, there is no noise disturbance: the sound power level is under 40 dB(A).
Advantages:
Technical specifications:
Feature | Value |
---|---|
Brand | Inventum |
Supplier code | 62010010 |
EAN Code | 8716453009737 |
Discount group | 110 |
Width | 500 mm |
Height | 570 mm |
Depth | 500 mm |
Weight | 45 kg |
Number of phases | 1 |
Control type | On/Off |
Cascadeable | No |
Refrigerant amount | 0.58 kg |
Remote control | No |
Device fuse | 16 A |
Frequency | 50 Hz |
Protection rating (IP) | Other |
Connection voltage | 230 - 230 |
Max heating supply temperature | 60 °C |
Airflow | 50 - 350 |
Noise level (in operation) | 0 - 41.5 |
Data transfer via USB | Yes |
Suitable for auxiliary heating (CV) | Yes |
Control for CV boiler | Yes |
Control for buffer tank | No |
External control required | No |
Data transfer via bus connection | Yes |
Pump type (system pump) | Energy-saving |
Pump voltage (system pump) | DC |
Pump speed control (system pump) | Built-in |
Speed control type (system pump) | Automatically regulated by dT |
Soft starter built-in | No |
Max power consumption limitation | 5 A |
Suitable for active cooling | No |
Hot water control integrated | No |
SEER for low-temperature application (35°C) under average conditions | 196 |
Energy efficiency class space heating | A++ |
COPd at Tj=+7°C | 4.99 |
Refrigerant content | 0.58 kg |
Global Warming Potential (GWP) | 1430 |
Suitable for hot water | No |
Room temperature control | Yes |
Suitable for pool water heating | No |
Sound power (Lwa) according to EN 12102 at 0/35°C | 41.5 dB |
Max operating pressure of delivery system | 3 bar |
Outer pipe diameter of delivery system connection | 15 mm |
Heating capacity at 7/35°C according to EN 14511 | 1.6 kW |
COP at 7/35°C according to EN 14511 | 5.14 |
Data transfer via internet | No |
Connecting and controlling multiple delivery systems possible | No |
Optimization type | OpenTherm |
Modulating compressor | No |