The new Remeha Quinta boiler has been designed with an unparalleled focus on efficiency, flexibility, and sustainability. With a power range from 45 to 115 kW, this boiler is the ideal solution for modern heating and hot water installations. It not only meets today’s requirements but is also prepared for future challenges.
The Quinta is a model of innovation, without losing sight of the solid foundation of proven technology. Thanks to the reliable heat exchanger, already successfully used in the Quinta Ace, this boiler provides a trusted foundation. This ensures not only reliable operation but also familiar elements for the installer.
Note: The Remeha Quinta can be used in combination with hot water storage tanks. According to VEWIN water regulations, for boilers above 45 kW, a double partition wall is required.
Feature | Value |
---|---|
Brand | Remeha |
Supplier Code | 7843856 |
EAN Code | 8713809373269 |
Discount Group | 005 |
Width | 500 mm |
Height | 750 mm |
Depth | 476 mm |
Number of Phases | 1 |
Supply Connection | External thread |
Return Connection | External thread |
Frequency | 50 Hz |
Sealed System | Yes |
Supplementary Electricity Consumption at Full Load (ELmax) | 0.169 kW |
Useful Heat Output at Nominal Heat Output (P4) | 103.9 kW |
Efficiency at High Temperature Operation (n4) | 87.4% |
Supplementary Electricity Consumption in Standby Mode (Psb) | 0.005 kW |
Standby Heat Loss (Pstby) | 0.123 kW |
Max. Hydrogen Percentage in Natural Gas Mixture | 20% |
Suitable for Low-Calorific Natural Gas | Standard factory setting |
Suitable for High-Calorific Natural Gas | Manually adjustable |
Suitable for Propane | With conversion kit (not included) |
Suitable for Butane | Not suitable |
Suitable for Methane | Standard factory setting |
Suitable for LPG | Not suitable |
Suitable for Hydrogen | Standard factory setting |
Heat Exchanger Material | Aluminum |
Built-in Pump Control | No |
Nominal Heat Input (Min.) | 19.6 kW |
Nominal Heat Input (Max.) | 107 kW |
Min. Operating Pressure | 0.8 bar |
Max. Gas Supply Pressure | 30 mbar |
Built-in Weather-Dependent Control | No |
Built-in Expansion Vessel | No |
Water-Side Resistance at ΔT 20 °C | 25 kPa |
Nominal Power at 80-60 °C | 103.9 kW |
Max. Flow Temperature (Operating Temperature) | 90 °C |
Max. Operating Pressure | 4 bar |
Built-in Fill/Drain Valve | No |
Built-in Pressure Relief Valve | No |
Fuel Connection | External thread |
Nominal Channel Diameter Air Supply | 100 mm |
Flue Gas Connection | Socket end |
Condensate Connection | Flexible |
Min. Gas Supply Pressure | 20 mbar |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Condensing | Yes |
Efficiency | 97.3% |
Pilot Flame | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | Yes |
Control Signal OpenTherm | Yes |
Operation as Open System (Air Supply Possible) | Yes |
Nominal Power at 50-30 °C | 109.7 kW |
Nominal Diameter Supply | 1 1/4" (32) |
Nominal Diameter Return | 1 1/4" (32) |
Nominal Diameter Fuel | 3/4" (20) |
Nominal Diameter Condensate | Other |