Brand |
Remeha |
Supplier Code |
7683600 |
EAN Code |
8713809304461 |
Discount Group |
005 |
Width |
500 mm |
Height |
750 mm |
Depth |
500 mm |
Voltage |
230 V |
Number of Phases |
1 |
Material Quality |
Other |
Supply Connection |
External thread |
Return Connection |
External thread |
Frequency |
50 Hz |
Connection Voltage |
196 - 253 V |
Closed Version |
Yes |
SEER (Ns) at cooler conditions |
97.3 |
SEER (Ns) at warmer conditions |
87.5 |
Supplementary Electricity Consumption at Full Load (ELmax) |
0.232 kW |
Useful Heat Output at Nominal Heat Output and Operation at High Temperature (P4) |
107 kW |
Efficiency at Nominal Heat Output and Operation at High Temperature (n4) |
87.5% |
Supplementary Electricity Consumption in Standby Mode (Psb) |
0.006 kW |
Standby Heat Loss (Pstby) |
0.123 kW |
Max. Hydrogen Percentage in Mixing with NAT Gas |
20% |
Suitable for Low Calorific Value Natural Gas |
Standard factory setting |
Suitable for High Calorific Value Natural Gas |
Manually adjustable |
Suitable for Propane |
With conversion kit, not included |
Suitable for Butane |
Not suitable |
Suitable for Methane |
Standard factory setting |
Suitable for LPG |
Not suitable |
Suitable for Hydrogen |
Standard factory setting |
Heat Exchanger Material |
Aluminum |
Built-in Pump Switch |
Yes |
Gas Approval VR/SV |
No |
Gas Approval NZ |
No |
Nominal Load Lower Limit |
107 kW |
Nominal Load Upper Limit |
45,600 kW |
Min. Operating Pressure |
0.8 bar |
Min. Return Temperature |
20 °C |
Built-in Weather-dependent Regulator |
No |
Built-in Expansion Vessel |
No |
Hydraulic Resistance at dT 20 °C |
25 kPa |
Nominal Power 80-60 °C |
103.9 kW |
Max. Supply Temperature (Operating Temperature) |
90 °C |
Built-in Fill/Drain Valve |
No |
Built-in Overpressure Valve |
No |
External Pipe Diameter Supply |
31.75 mm |
External Pipe Diameter Return |
31.75 mm |
Fuel Connection |
External thread |
External Pipe Diameter Fuel |
19.05 mm |
Air Supply Connection |
Push-fit end |
Nominal Air Supply Pipe Diameter |
80 mm |
Flue Gas Pipe Connection |
Push-fit end |
Condensate Connection |
Flexible |
External Pipe Diameter Condensate |
25 mm |
Suitable for Natural Gas |
Yes |
Gas Approval VR |
No |
Nominal Flue Gas Pipe Diameter |
100 mm |
Burner Control High/Low |
No |
Burner Control Modulating |
Yes |
External Pipe Diameter Expansion Connection |
0 mm |
Built-in Manometer |
Yes |
Condensing |
Yes |
Gas Approval HR |
Yes |
Efficiency |
107% |
Pilot Flame |
No |
Second Return Connection |
No |
Control Signal On/Off |
Yes |
Control Signal High/Low |
No |
Control Signal 0-10V |
Yes |
Control Signal OpenTherm |
Yes |
Operation as Open Version (Air Supply) Possible |
Yes |
Nominal Power 50-30 °C |
109.7 kW |
Suitable for Propane |
Yes |
Suitable for Butane |
No |
Suitable for Methane |
Yes |
Max. Permissible Operating Pressure |
4 bar |
Nominal Supply Diameter |
1 1/4" (32) |
Nominal Return Diameter |
1 1/4" (32) |
Nominal Fuel Diameter |
3/4" (20) |
Nominal Condensate Diameter |
DN 25 |
Conversion Kit Required |
No |
Gas Approval HR |
Yes |
Gas Approval NZ |
No |