The Remeha Tzerra Ace-Matic is a boiler with guaranteed high and sustainable efficiency. This revolutionary boiler is equipped with an electronic, self-adjusting gas/air system. This ensures optimal settings and guarantees a high and lasting efficiency. Furthermore, the Tzerra Ace-Matic is future-ready.
Sustainable High Efficiency
The Tzerra Ace-Matic adjusts automatically. Not only at installation by the installer but also afterwards. The device continuously checks whether the settings are still optimal. If not, it automatically adjusts itself. This ensures that the settings are always correct.
Future-Ready
Thanks to the deep modulation of 1:8, the device is ideally suited for connection with a hybrid heat pump. Additionally, this boiler is compatible with natural gas mixed with up to 20% hydrogen. With the built-in solar boiler control as standard, the Tzerra Ace-Matic can easily be connected to a solar boiler or other sustainable solutions.
Advantages of the Tzerra Ace-Matic
Note! This version is equipped with a concentric flue gas outlet.
Feature | Value |
---|---|
Brand | Remeha |
Supplier Code | 7826397 |
EAN Code | 8713809361341 |
Discount Group | 005 |
Width | 395 mm |
Height | 700 mm |
Depth | 285 mm |
Number of Phases | 1 |
Flow Connection | Compression |
Return Connection | Compression |
Nominal Voltage | 196 - 253 V |
Frequency | 50 Hz |
Closed Design | Yes |
Water Heating Energy Efficiency (Nwh) | 89% |
SEER (Ns) under average conditions | 94% |
SEER (Ns) under colder conditions | 99.4% |
SEER (Ns) under warmer conditions | 88% |
Capacity Profile | XL |
Nominal Diameter Hot Water | DN 15 |
Additional Power Consumption at Full Load (ELmax) | 0.033 kW |
Useful Heat Output at Nominal Heat Output and High-Temperature Operation (P4) | 20 kW |
Useful Efficiency at Nominal Heat Output and High-Temperature Operation (n4) | 88% |
Additional Power Consumption in Standby Mode (Psb) | 0.004 kW |
Standby Heat Loss (Pstby) | 0.04 kW |
With Built-in Economizer | Yes |
Space Heating Energy Efficiency | 94% |
Max. Percentage of Hydrogen in Natural Gas Mix | 20% |
Suitable for Low-Calorific Natural Gas | Automatically Adjustable |
Suitable for High-Calorific Natural Gas | Automatically Adjustable |
Suitable for Propane | With Conversion Kit, Not Included |
Suitable for Butane | Automatically Adjustable |
Suitable for Methane | Automatically Adjustable |
Suitable for LPG | Automatically Adjustable |
Suitable for Hydrogen | Not Suitable |
Heat Exchanger Material | Stainless Steel (SS) |
Adjustable Heating Capacity | Yes |
Nominal Diameter Cold Water | DN 15 |
Minimum Flow Rate | 1.2 l/min |
Built-in Pump Switching | Yes |
Nominal Load Lower Value | 24.7 kW |
Nominal Load Upper Value | 27.4 kW |
Min. Return Temperature | 20 °C |
Max. Gas Supply Pressure | 30 mbar |
Hot Water Capacity at 60 °C | 6.9 l/min |
Built-in Weather-Dependent Controller | Yes |
Built-in Expansion Vessel | No |
Water Side Resistance at ΔT 20 °C | 24 kPa |
Nominal Output 80-60 °C | 20 kW |
Max. Flow Temperature (Operating Temperature) | 80 °C |
Built-in Filling/Drain Valve | No |
Built-in Pressure Relief Valve | Yes |
Outer Pipe Diameter Flow | 22 mm |
Outer Pipe Diameter Return | 22 mm |
Fuel Connection | Compression |
Outer Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Push-In |
Nominal Channel Diameter Air Supply | 100 mm |
Flue Gas Outlet Connection | Push-In |
Outer Pipe Diameter Cold Water | 15 mm |
Outer Pipe Diameter Hot Water | 15 mm |
Condensate Connection | Other |
Outer Pipe Diameter Condensate | 21.8 mm |
Min. Gas Supply Pressure | 20 mbar |
Hot Water Connection | Compression |
Nominal Channel Diameter Flue Gas Outlet | 60 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Condensing | Yes |
Efficiency | 99.4% |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | No |
Control Signal High/Low | No |
Control Signal 0-10V | No |
Control Signal OpenTherm | No |
Operation as Open System (Air Supply) Possible | Yes |
Nominal Output 50-30 °C | 21.8 kW |
Nominal Diameter Flow | Other |
Nominal Diameter Return | Other |
Nominal Diameter Fuel | DN 15 |
Hot Water Storage | 1 l |
Conversion Kit Required | No |
Built-in Intake Combination | No |
CW Label | 3 |
Gaskeur HR | Yes |