The Remeha Tzerra Ace-Matic is a boiler with guaranteed high and lasting efficiency. This revolutionary boiler is equipped with an electronic, self-adjusting gas/air system. This ensures optimal settings and guarantees a high, lasting efficiency. Furthermore, the Tzerra Ace-Matic is future-proof.
Consistently High Efficiency
The Tzerra Ace-Matic adjusts itself fully automatically. Not only at installation by the installer but also afterward. The unit continuously checks if the settings are still optimal. If not, the unit automatically adjusts itself. This means you are always assured of the correct settings.
Future-Proof
Thanks to the deep modulation of 1:8, the device is ideally suited for connection with a hybrid heat pump. Moreover, this boiler is suitable for natural gas with a 20% hydrogen blend. With the standard built-in solar boiler regulation, the Tzerra Ace-Matic can be easily connected to a solar boiler or other sustainable solutions.
Benefits of the Tzerra Ace-Matic
Note! This version is equipped with an eccentric (parallel) flue gas discharge.
Feature | Value |
---|---|
Brand | Remeha |
Supplier Code | 7814162 |
EAN Code | 8713809361372 |
Discount Group | 005 |
Width | 395 mm |
Height | 700 mm |
Depth | 285 mm |
Number of Phases | 1 |
Supply Connection | Compression fitting |
Return Connection | Compression fitting |
Nominal Voltage | 196 - 253 V |
Frequency | 50 Hz |
Closed Version | Yes |
Water Heating Efficiency (Nwh) | 87% |
SEER (Ns) under average conditions | 94% |
SEER (Ns) under colder conditions | 98.9% |
SEER (Ns) under warmer conditions | 88.1% |
Capacity Profile | XL |
Nominal Diameter of Hot Water | DN 15 |
Supplementary Power Consumption under Full Load (ELmax) | 0.055 kW |
Useful Heat Output at Nominal Heat Output and Operation at High Temperature (P4) | 30 kW |
Useful Efficiency at Nominal Heat Output and Operation at High Temperature (n4) | 88.1% |
Supplementary Power Consumption in Standby Mode (Psb) | 0.004 kW |
Standby Heat Loss (Pstby) | 0.04 kW |
With Built-in Economizer | Yes |
Energy Efficiency for Space Heating | 94% |
Max Hydrogen Percentage in Blend with Natural Gas | 20% |
Suitable for Low Calorific Value Natural Gas | Automatically adjustable |
Suitable for High Calorific Value Natural Gas | Automatically adjustable |
Suitable for Propane | Requires conversion kit (not included) |
Suitable for Butane | Automatically adjustable |
Suitable for Methane | Automatically adjustable |
Suitable for LPG | Automatically adjustable |
Suitable for Hydrogen | Not suitable |
Heat Exchanger Material | Stainless steel (SS) |
Adjustable Heating Power | Yes |
Nominal Diameter of Cold Water | DN 15 |
Minimum Flow Rate | 1.2 l/min |
Built-in Pump Switching | Yes |
Nominal Load Lower Limit | 36 kW |
Nominal Load Upper Limit | 39.96 kW |
Min. Return Temperature | 20°C |
Max. Gas Inlet Pressure | 30 mbar |
Hot Water Capacity at 60°C | 10 l/min |
Built-in Weather-Dependent Regulator | Yes |
Built-in Expansion Tank | No |
Hydraulic Resistance at dT 20°C | 27 kPa |
Nominal Power 80-60°C | 30 kW |
Max. Supply Temperature (Operating Temperature) | 80°C |
Built-in Filling/Draining Valve | No |
Built-in Pressure Relief Valve | Yes |
External Pipe Diameter for Supply | 22 mm |
External Pipe Diameter for Return | 22 mm |
Fuel Connection | Compression fitting |
External Pipe Diameter for Fuel | 15 mm |
Air Supply Connection | Push-fit |
Nominal Channel Diameter for Air Supply | 80 mm |
Flue Gas Connection | Push-fit |
External Pipe Diameter for Cold Water | 15 mm |
External Pipe Diameter for Hot Water | 15 mm |
Condensate Connection | Other |
External Pipe Diameter for Condensate | 21.8 mm |
Min. Gas Inlet Pressure | 20 mbar |
Hot Water Connection | Compression fitting |
Nominal Channel Diameter for Flue Gas | 80 mm |
Burner Control High/Low | No |
Burner Control Modulating | Yes |
Built-in Manometer | Yes |
Condensing | Yes |
Efficiency | 98.9% |
Pilot Flame | No |
Second Return Connection | No |
Regulation Signal On/Off | No |
Regulation Signal High/Low | No |
Regulation Signal 0-10V | No |
Regulation Signal OpenTherm | No |
Operation Possible as Open Version (Air Supply) | Yes |
Nominal Power 50-30°C | 32.8 kW |
Nominal Diameter of Supply | Other |
Nominal Diameter of Return | Other |
Nominal Diameter of Fuel | DN 15 |
Hot Water Storage | 1 l |
Conversion Kit Required | No |
Built-in Inlet Combination | No |
CW Label | 5 |
Gas Certification HR | Yes |