The Vaillant ecoTEC exclusive is an intelligent gas condensing boiler with very high domestic hot water comfort. The ecoTEC exclusive uses a brand-new monitoring electrode that ensures optimized combustion. This unique combustion technology guarantees that energy is always used as efficiently as possible, while emissions remain as low as possible.
Compact wall-mounted boiler with intuitive controls
The design of the ecoTEC exclusive is specifically developed to seamlessly integrate even into the smallest spaces. It is suitable for both large homes and smaller apartments. Additionally, we have enhanced the user interface with a user-friendly touch screen display.
Independent of varying gas qualities
Thanks to intelligent IoniDetect technology, the boiler automatically adjusts to different gas qualities. This ensures the highest energy efficiency and the lowest heating costs. Moreover, the adaptability results in stable and long-lasting operation of the boiler with minimal maintenance efforts. The system operates automatically and always provides the highest comfort.
Features
Technical Specifications
Feature | Value |
---|---|
Brand | Vaillant |
Supplier Code | 0010024612 |
EAN Code | 4024074896785 |
Discount Group | 016 |
Width | 440 mm |
Height | 720 mm |
Depth | 450 mm |
Number of Phases | 1 |
Material Quality | Other |
Inlet Connection | Compression fittings |
Return Connection | Compression fittings |
Frequency | 50 Hz |
Closed Version | Yes |
Nominal Domestic Hot Water Output | 42.8 kW |
Nominal Upper Domestic Hot Water Load | 41 kW |
Nominal Lower Domestic Hot Water Load | 36.9 kW |
Water Heating Energy Efficiency (Nwh) | 91 % |
SEER (Ns) under average conditions | 94 |
SEER (Ns) under colder conditions | 98.5 |
SEER (Ns) under warmer conditions | 88.4 |
Capacity Profile | XXL |
Energy Efficiency Class Space Heating | A |
Energy Efficiency Class Water Heating | A |
Nominal Diameter Hot Water | 1/2" (15) |
Additional Electricity Consumption at Full Load (ELmax) | 0.046 kW |
Useful Heat Output at Nominal Heat Output and High Temperature Operation (P4) | 33.2 kW |
Useful Efficiency at Nominal Heat Output and High Temperature (n4) | 88.4 % |
Additional Electricity Consumption in Standby Mode (Psb) | 0.002 kW |
Standby Heat Loss (Pstby) | 0.064 kW |
Energy Efficiency Space Heating | 94 % |
Hot Water Flow Rate according to EN 13203-1 | 13.5 l/min |
Max. Hydrogen Content in Natural Gas Mixture | 0 % |
Suitable for Low Calorific Value Natural Gas | Standard factory setting |
Suitable for High Calorific Value Natural Gas | Automatically adjustable |
Suitable for Propane | Not suitable |
Suitable for Butane | Not suitable |
Suitable for Methane | Automatically adjustable |
Suitable for LPG | Not suitable |
Energy Efficiency Class Space Heating (811/2013/EU) | A |
Energy Efficiency Class Water Heating (811/2013/EU) | A |
Nominal Load | 5 - 38 kW |
Gas Supply Pressure | 17 - 30 mbar |
Nominal Hot Water Load | 5 - 44.4 kW |
Seasonal Energy Efficiency for Space Heating (ηs, h) | 94 % |
Heat Exchanger Material | Stainless Steel (SS) |
Heating Power Adjustable | Yes |
Nominal Cold Water Diameter | 1/2" (15) |
Flow Threshold | 1.8 l/min |
Built-in Pump Switch | Yes |
Gas Certification VR/SV | No |
Gas Certification NZ | Yes |
Nominal Lower Load | 34.2 kW |
Nominal Upper Load | 38 kW |
Min. Operating Pressure | 0.3 bar |
Min. Return Temperature | 1 °C |
Max. Gas Supply Pressure | 30 mbar |
Hot Water Capacity at 60 °C | 12.2 l/min |
Built-in Weather Dependent Regulator | No |
Built-in Expansion Vessel | No |
Nominal Power 80-60 °C | 33.2 kW |
Max. Flow Temperature (Operating Temperature) | 85 °C |
Max. Operating Pressure | 3 bar |
Built-in Fill/Drain Valve | No |
External Pipe Diameter Inlet | 22 mm |
External Pipe Diameter Return | 22 mm |
Fuel Connection | Compression fittings |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Plug-in end |
Nominal Pipe Diameter Air Supply | 80 mm |
Flue Gas Connection | Plug-in end |
External Pipe Diameter Cold Water | 15 mm |
External Pipe Diameter Hot Water | 15 mm |
Condensate Connection | Flexible |
External Pipe Diameter Condensate | 25 mm |
Min. Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Certification VR | No |
Cold Water Connection | Compression fittings |
Hot Water Connection | Compression fittings |
Nominal Pipe Diameter Flue Gas | 80 mm |
Burner Control High/Low | No |
Burner Control Modulating | Yes |
Built-in Manometer | Yes |
Condensing | Yes |
Gas Certification HR | Yes |
Efficiency | 107 % |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | Yes |
Control Signal OpenTherm | Yes |
Operation as Open Version (Air Supply) | Yes |
Nominal Power 50-30 °C | 36 kW |
Suitable for Propane | No |
Suitable for Butane | No |
Suitable for Methane | Yes |
Max. Allowable Operating Pressure | 3 bar |
Nominal Inlet Pipe Diameter | 3/4" (20) |
Nominal Return Pipe Diameter | 3/4" (20) |
Nominal Fuel Pipe Diameter | 1/2" (15) |
Hot Water Storage | 0 l |
Nominal Condensate Pipe Diameter | DN 25 |
Conversion Kit Required | No |
Operating Pressure | 0.3 - 3 |
Built-in Inlet Combination | No |
CW Label | 5 |
Gas Certification HR | Yes |
Gas Certification NZ | Yes |