The Vaillant ecoTEC plus combines high quality, minimal consumption, and optimal heat comfort. With the ecoTEC plus, you can heat intelligently without compromising on proven quality. This powerful HR boiler has a CW3 class and delivers 12.3 liters of hot water per minute (at 60 degrees).
The ecoTEC plus is a sealed unit with an additional safety metal casing, acoustic insulation, and a safety siphon that prevents the leakage of combustion gases. The boiler ensures reliable operation. This means that the unit will continue to provide heat even if one of the components temporarily fails.
Future-Proof
In the future, it may be possible to heat with natural gas containing up to 20% hydrogen. Hydrogen is a promising energy source that could eventually make the transition to a CO2-neutral energy supply possible. Our ecoTEC plus is already compatible with a 20% hydrogen blend in natural gas. The boiler has been extensively tested and validated to safely and without modification heat homes and provide hot water with 20% hydrogen.
Additionally, the ecoTEC plus is hybrid-ready; the heating system can be expanded with a heat pump. This way, you can use renewable energy sources and heat more efficiently than ever before. Management or remote control is possible with the optional sensoNET gateway in combination with the sensoAPP.
Advantages
Technical Specifications
Feature | Value |
---|---|
Brand | Vaillant |
Supplier Code | 0010043921 |
EAN Code | 4024074921159 |
Discount Group | 016 |
Width | 440 mm |
Height | 720 mm |
Depth | 348 mm |
Number of Phases | 1 |
Supply Connection | Compression fitting |
Return Connection | Compression fitting |
Nominal Voltage | 230 V |
Frequency | 50 Hz |
Sealed Unit | Yes |
Nominal Hot Water Output | 26 kW |
Nominal Upper Load for Hot Water | 29.4 kW |
Nominal Lower Load for Hot Water | 26.5 kW |
Energy Efficiency for Water Heating (Nwh) | 76 % |
SEER (Ns) under Average Conditions | 94 |
SEER (Ns) under Cooler Conditions | 87.6 |
SEER (Ns) under Warmer Conditions | 98.9 |
Capacity Profile | M |
Energy Efficiency Class for Space Heating | A |
Energy Efficiency Class for Water Heating | A |
Nominal Diameter Hot Water | 1/2" (15) |
Additional Electricity Consumption at Full Load (ELmax) | 0.032 kW |
Useful Heat Output at Nominal Heat Output and High Temperature (P4) | 19.8 kW |
Useful Efficiency at Nominal Heat Output and High Temperature (n4) | 87.6 % |
Additional Electricity Consumption in Standby Mode (Psb) | 0.002 kW |
Standby Heat Loss (Pstby) | 0.048 kW |
With Built-in Economizer | No |
Energy Efficiency for Space Heating | 94 % |
Hot Water Flow Rate according to EN 13203-1 | 8.1 l/min |
Max. Hydrogen Percentage in Natural Gas | 20 % |
Suitable for Low Calorific Gas | Standard factory setting |
Suitable for High Calorific Gas | Automatically adjustable |
Suitable for Propane | Manually adjustable |
Suitable for Butane | Not suitable |
Suitable for Methane | Automatically adjustable |
Suitable for LPG | Not suitable |
Suitable for Hydrogen | Automatically adjustable |
Energy Efficiency Class for Space Heating (811/2013/EU) | A |
Energy Efficiency Class for Water Heating (811/2013/EU) | A |
Nominal Load | 3.6 - 29.4 |
Gas Supply Pressure | 17 - 30 |
Nominal Hot Water Load | 3.6 - 29.4 |
ηs, h (Seasonal Energy Efficiency for Space Heating) | 94 % |
Heat Exchanger Material | Stainless Steel (SS) |
Heating Capacity Adjustable | Yes |
Nominal Diameter Cold Water | 1/2" (15) |
Water Flow Rate | 2 l/min |
Built-in Pump Switch | Yes |
Nominal Lower Load | 26.5 kW |
Nominal Upper Load | 29.4 kW |
Min. Operating Pressure | 0.3 bar |
Min. Return Temperature | 1 °C |
Max. Gas Supply Pressure | 30 mbar |
Hot Water Capacity at 60 °C | 7.3 l/min |
Built-in Weather-Dependent Controller | No |
Built-in Expansion Vessel | No |
Nominal Power at 80-60 °C | 19.7 kW |
Max. Supply Temperature (Operating Temperature) | 85 °C |
Max. Operating Pressure | 3 bar |
Built-in Fill/Drain Valve | No |
Built-in Overpressure Valve | Yes |
External Pipe Diameter Supply | 22 mm |
External Pipe Diameter Return | 22 mm |
Fuel Connection | Compression fitting |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Push-fit |
Nominal Air Supply Pipe Diameter | 80 mm |
Flue Gas Connection | Push-fit |
External Pipe Diameter Cold Water | 15 mm |
External Pipe Diameter Hot Water | 15 mm |
Condensate Connection | Flexible |
External Pipe Diameter Condensate | 25 mm |
Min. Gas Supply Pressure | 20 mbar |
Cold Water Connection | Compression fitting |
Hot Water Connection | Compression fitting |
Nominal Flue Gas Pipe Diameter | 80 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Condensing | Yes |
Efficiency | 107 % |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | Yes |
Control Signal OpenTherm | Yes |
Operation as Open Version (Air Supply Possible) | Yes |
Nominal Power at 50-30 °C | 21 kW |
Nominal Supply Pipe Diameter | 3/4" (20) |
Nominal Return Pipe Diameter | 3/4" (20) |
Nominal Fuel Pipe Diameter | 1/2" (15) |
Hot Water Storage | 0 l |
Nominal Condensate Pipe Diameter | DN 20 |
Conversion Kit Required | No |
Operating Pressure | 0.3 - 3 |
Built-in Inlet Combination | No |
CW Label | 3 |
Gaskeur HR | Yes |
Gaskeur NZ | Yes |