Vaillant ecoTEC plus combines high quality, minimal consumption, and optimal heat comfort. With the ecoTEC plus, you can heat intelligently without compromising on proven quality. The ecoTEC plus is a sealed unit with an extra-safe metal casing with acoustic insulation and a safety siphon that prevents the leakage of combustion gases. The unit ensures reliable operation, meaning it will continue to provide heat, even if one of the components temporarily fails.
Future-Proof
It may be possible in the future to heat with natural gas that contains up to 20% hydrogen. Hydrogen is a promising energy source that could eventually make the transition to a CO2-neutral energy supply possible. Our ecoTEC plus is already suitable for the blending of 20% hydrogen into natural gas. The boiler has been thoroughly tested and validated to safely heat homes and provide hot water with 20% hydrogen, without the need for any modifications.
In addition, the ecoTEC plus is hybrid-ready; the heating system can be expanded with a heat pump. This allows you to take advantage of renewable energy sources and heat more efficiently than ever before. Management or remote control is possible with the optional sensoNET gateway in combination with the sensoAPP.
Advantages:
Technical Specifications:
Feature | Value |
---|---|
Brand | Vaillant |
Supplier Code | 0010021526 |
EAN Code | 4024074823552 |
Discount Group | 017 |
Width | 440 mm |
Height | 720 mm |
Depth | 405 mm |
Voltage | 230 V |
Number of Phases | 1 |
Energy Efficiency Class | A |
Material Quality | Other |
Supply Connection | External thread |
Return Connection | External thread |
Frequency | 50 Hz |
Connection Voltage | 230 V |
Sealed Unit | Yes |
SEER (Ns) under average conditions | 92 |
SEER (Ns) under colder conditions | 97 |
SEER (Ns) under warmer conditions | 88.1 |
Supplementary electricity consumption at full load (ELmax) | 0.03 kW |
Useful heat output at nominal heat output and operation at high temperature (P4) | 41 kW |
Useful efficiency at nominal heat output and operation at high temperature (n4) | 88.1 % |
Supplementary electricity consumption in standby mode (Psb) | 0 kW |
Standby heat loss (Pstby) | 0.04 kW |
Max. hydrogen blend with natural gas | 0 % |
Suitable for low-calorific natural gas | Standard factory setting |
Suitable for high-calorific natural gas | Manually adjustable |
Suitable for propane | With conversion kit, not included |
Suitable for butane | Not suitable |
Suitable for methane | Not suitable |
Suitable for LPG | Not suitable |
Suitable for hydrogen | Not suitable |
Energy Efficiency Class for Space Heating (811/2013/EU) | A |
Nominal load | 9 - 46.7 kW |
Gas Supply Pressure | 17 - 30 mbar |
ηs, h (seasonal energy efficiency for space heating) | 92 % |
Heat Exchanger Material | Stainless Steel (SS) |
Built-in Pump Control | Yes |
Gas Certification VR/SV | Yes |
Gas Certification NZ | No |
Nominal load lower limit | 42 kW |
Nominal load upper limit | 46.7 kW |
Min. operating pressure | 0.5 bar |
Min. return temperature | 1 °C |
Max. gas supply pressure | 30 mbar |
Built-in weather-dependent control | No |
Built-in expansion vessel | No |
Nominal power 80-60 °C | 41 kW |
Max. supply temperature (operating temperature) | 75 °C |
Max. operating pressure | 3 bar |
Built-in fill/drain valve | No |
Built-in pressure relief valve | Yes |
External pipe diameter supply | 40 mm |
External pipe diameter return | 40 mm |
Fuel connection | Internal thread |
External pipe diameter fuel | 25 mm |
Air supply connection | Coupling |
Nominal air supply pipe diameter | 80 mm |
Flue gas discharge connection | Coupling |
Condensate connection | Flexible |
External pipe diameter condensate | 25 mm |
Min. gas supply pressure | 20 mbar |
Suitable for natural gas | Yes |
Gas Certification VR | No |
Nominal flue gas discharge pipe diameter | 80 mm |
Burner control high/low | No |
Modulating burner control | Yes |
Built-in manometer | Yes |
Gas Certification HR | Yes |
Efficiency | 107 % |
Pilot flame | No |
Second return connection | No |
Control signal on/off | Yes |
Control signal high/low | No |
Control signal 0-10V | No |
Control signal OpenTherm | No |
Operation as open unit (air supply) possible | Yes |
Nominal power 50-30 °C | 44.6 kW |
Suitable for propane | Yes |
Suitable for butane | No |
Suitable for methane | No |
Max. allowable operating pressure | 4 bar |
Nominal pipe diameter supply | 1 1/2" (40) |
Nominal pipe diameter return | 1 1/2" (40) |
Nominal pipe diameter fuel | 1" (25) |
Nominal pipe diameter condensate | 3/4" (20) |
Conversion kit required | Yes |
Operating pressure | 0.3 - 4 bar |
CW Label | 0 |
Gas Certification HR | Yes |
Gas Certification NZ | No |