Vaillant ecoTEC plus combines high quality, minimal consumption, and optimal heating comfort. With the ecoTEC plus, you can heat smartly without compromising on proven quality. The ecoTEC plus is a closed boiler with an extra-safe metal casing, acoustic insulation, and a safety siphon that prevents the leakage of combustion gases. The boiler ensures reliable operation, meaning that it will continue to provide heat, even if one of the components temporarily fails.
Future-Proof
In the future, it might be possible to heat with natural gas that is mixed with up to 20% hydrogen. Hydrogen is a promising energy source that could eventually enable the transition to a CO2-neutral energy supply. Our ecoTEC plus is already suitable for the mixing of 20% hydrogen with natural gas. The boiler has been extensively tested and validated to safely heat homes and provide hot water with 20% hydrogen without any adjustments.
In addition, the ecoTEC plus is hybrid-ready; the heating system can be expanded with a heat pump. This allows you to use renewable energy sources and heat more efficiently than ever before. Control or remote control is possible with the optional sensoNET gateway in combination with the sensoAPP.
Benefits:
Technical Specifications:
Feature | Value |
---|---|
Brand | Vaillant |
Supplier Code | 0010021527 |
EAN Code | 4024074823606 |
Discount Group | 017 |
Width | 440 mm |
Height | 720 mm |
Depth | 473 mm |
Power Supply Voltage | 230 V |
Number of Phases | 1 |
Energy Efficiency Class | A |
Material Quality | Other |
Flow Connection | External Thread |
Return Connection | External Thread |
Frequency | 50 Hz |
Connection Voltage | 230 - 230 V |
Closed Design | Yes |
SEER (Ns) under average conditions | 94 |
SEER (Ns) under colder conditions | 98.6 |
SEER (Ns) under warmer conditions | 88.5 |
Additional Electricity Consumption at Full Load (ELmax) | 0.03 kW |
Useful Heat Output at Nominal Heat Output and High-Temperature Operation (P4) | 58.7 kW |
Useful Efficiency at Nominal Heat Output and High-Temperature Operation (n4) | 88.5 % |
Additional Electricity Consumption in Standby Mode (Psb) | 0 kW |
Standby Heat Loss (Pstby) | 0.04 kW |
Max. Hydrogen Mixing Percentage with NAT Gas | 0 % |
Suitable for Low Calorific Value Natural Gas | Standard Factory Setting |
Suitable for High Calorific Value Natural Gas | Manually Adjustable |
Suitable for Propane | Manually Adjustable |
Suitable for Butane | Not Suitable |
Suitable for Methane | Not Suitable |
Suitable for LPG | Not Suitable |
Suitable for Hydrogen | Not Suitable |
Energy Efficiency Class for Space Heating (811/2013/EU) | A |
Nominal Load | 12.6 - 66.7 kW |
Gas Supply Pressure | 17 - 30 mbar |
ηs, h (Seasonal Energy Efficiency for Space Heating) | 94 % |
Heat Exchanger Material | Stainless Steel (SS) |
Built-in Pump Switching | Yes |
Gas Certification VR/SV | Yes |
Gas Certification NZ | No |
Nominal Load Lower Limit | 60 kW |
Nominal Load Upper Limit | 66.7 kW |
Min. Working Pressure | 0.5 bar |
Min. Return Temperature | 1 °C |
Max. Gas Supply Pressure | 30 mbar |
Built-in Weather Dependent Controller | No |
Built-in Expansion Tank | No |
Nominal Output 80-60 °C | 58.7 kW |
Max. Flow Temperature (Operating Temperature) | 75 °C |
Max. Working Pressure | 3 bar |
Built-in Fill/Drain Valve | No |
Built-in Pressure Relief Valve | Yes |
External Pipe Diameter Flow | 40 mm |
External Pipe Diameter Return | 40 mm |
Fuel Connection | Internal Thread |
External Pipe Diameter Fuel | 25 mm |
Air Supply Connection | Socket |
Nominal Pipe Diameter Air Supply | 80 mm |
Flue Gas Outlet Connection | Socket |
Condensate Connection | Flexible |
External Pipe Diameter Condensate | 25 mm |
Min. Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Certification VR | No |
Nominal Pipe Diameter Flue Gas Outlet | 80 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Built-in Manometer | Yes |
Gas Certification HR | Yes |
Efficiency | 107 % |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | No |
Control Signal OpenTherm | No |
Open Design Operation (Air Supply) Possible | Yes |
Nominal Output 50-30 °C | 63.5 kW |
Suitable for Propane | Yes |
Suitable for Butane | No |
Suitable for Methane | No |
Max. Allowable Operating Pressure | 4 bar |
Nominal Diameter Flow | 1 1/2" (40) |
Nominal Diameter Return | 1 1/2" (40) |
Nominal Diameter Fuel | 1" (25) |
Nominal Diameter Condensate | 3/4" (20) |
Conversion Kit Required | Yes |
Operating Pressure | 0.3 - 4 bar |
CW Label | 0 |
Gas Certification HR | Yes |
Gas Certification NZ | No |