The Vaillant ecoTEC plus combines high quality, minimal consumption, and optimal heating comfort. With the ecoTEC plus, you can heat intelligently without compromising proven quality. The ecoTEC plus is a sealed boiler with an extra-safe metal casing, acoustic insulation, and a safety siphon that prevents the leakage of combustion gases. The boiler guarantees reliable operation, which means it continues to provide heat even if one of its components temporarily fails.
Future-Proof
In the future, it may be possible to heat using natural gas with up to 20% hydrogen mixed in. Hydrogen is a promising energy source that could ultimately enable the transition to a CO2-neutral energy supply. Our ecoTEC plus is already suitable for a 20% hydrogen blend with natural gas. The boiler has been thoroughly tested and validated to heat homes and supply hot water safely with 20% hydrogen, without any modifications.
Additionally, the ecoTEC plus is hybrid ready; the heating system can be expanded with a heat pump. This allows you to use renewable energy sources and heat more efficiently than ever before. Management or remote control is possible with the optional sensoNET gateway in combination with the sensoAPP.
Advantages:
Technical Specifications:
Feature | Value |
---|---|
Brand | Vaillant |
Supplier Code | 0010024615 |
EAN Code | 4024074896464 |
Discount Group | 017 |
Width | 440 mm |
Height | 720 mm |
Depth | 382 mm |
Number of Phases | 1 |
Energy Efficiency Class | A |
Material Quality | Other |
Flow Connection | Compression fitting |
Return Connection | Compression fitting |
Frequency | 50 Hz |
Closed Version | Yes |
SEER (Ns) under average conditions | 94 |
SEER (Ns) under colder conditions | 98.6 |
SEER (Ns) under warmer conditions | 88 |
Supplementary Electricity Consumption at Full Load (ELmax) | 0.022 kW |
Useful Heat Output at Nominal Heat Output and High Temperature (P4) | 34.6 kW |
Useful Efficiency at Nominal Heat Output and High Temperature (n4) | 88 % |
Supplementary Electricity Consumption in Standby Mode (Psb) | 0.002 kW |
Standby Heat Loss (Pstby) | 0.059 kW |
Max. Hydrogen Percentage in Blend with Natural Gas | 20 % |
Suitable for Low-Calorific Natural Gas | Standard factory setting |
Suitable for High-Calorific Natural Gas | Automatically adjustable |
Suitable for Propane | Not suitable |
Suitable for Butane | Not suitable |
Suitable for Methane | Automatically adjustable |
Suitable for LPG | Not suitable |
Suitable for Hydrogen | Not suitable |
Energy Efficiency Class for Space Heating (811/2013/EU) | A |
Nominal Load | 5.3 - 39.6 kW |
Gas Supply Pressure | 17 - 30 mbar |
ηs, h (Seasonal Energy Efficiency for Space Heating) | 94 % |
Material of Heat Exchanger | Stainless Steel (V2A) |
Integrated Pump Switch | Yes |
Gas Approval VR/SV | No |
Gas Approval NZ | No |
Nominal Load Lower Value | 35.7 kW |
Nominal Load Upper Value | 39.6 kW |
Minimum Operating Pressure | 0.3 bar |
Minimum Return Temperature | 1 °C |
Max. Gas Supply Pressure | 30 mbar |
Integrated Weather-Dependent Regulator | No |
Integrated Expansion Vessel | No |
Nominal Power 80-60 °C | 34.6 kW |
Max. Flow Temperature (Operating Temperature) | 85 °C |
Max. Operating Pressure | 3 bar |
Integrated Filling/Drain Valve | No |
Integrated Overpressure Valve | Yes |
External Pipe Diameter Flow | 22 mm |
External Pipe Diameter Return | 22 mm |
Fuel Connection | Other |
External Pipe Diameter Fuel | 15 mm |
Air Supply Connection | Push-fit |
Nom. Duct Diameter Air Supply | 80 mm |
Flue Gas Connection | Push-fit |
Condensate Connection | Flexible |
External Pipe Diameter Condensate | 25 mm |
Min. Gas Supply Pressure | 20 mbar |
Suitable for Natural Gas | Yes |
Gas Approval VR | No |
Nom. Duct Diameter Flue Gas Connection | 80 mm |
Burner Control High/Low | No |
Modulating Burner Control | Yes |
Integrated Manometer | Yes |
Condensing | Yes |
Gas Approval HR | Yes |
Efficiency | 107 % |
Pilot Flame | No |
Second Return Connection | No |
Control Signal On/Off | Yes |
Control Signal High/Low | No |
Control Signal 0-10V | Yes |
Control Signal OpenTherm | Yes |
Operation as Open Version (Air Supply) Possible | Yes |
Nom. Power 50-30 °C | 37.7 kW |
Suitable for Propane | No |
Suitable for Butane | No |
Suitable for Methane | Yes |
Max. Allowable Operating Pressure | 3 bar |
Nominal Diameter Flow | 3/4" (20) |
Nominal Diameter Return | 3/4" (20) |
Nominal Diameter Fuel | 1/2" (15) |
Nominal Diameter Condensate | DN 20 |
Conversion Kit Required | No |
Operating Pressure | 0.3 - 3 |
CW Label | 0 |
Gas Approval HR | Yes |
Gas Approval NZ | No |